Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.153
Filtrar
1.
Fam Med Community Health ; 12(Suppl 3)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609092

RESUMO

Storylines of Family Medicine is a 12-part series of thematically linked mini-essays with accompanying illustrations that explore the many dimensions of family medicine, as interpreted by individual family physicians and medical educators in the USA and elsewhere around the world. In 'IV: perspectives on practice-lenses of appreciation', authors address the following themes: 'Relational connections in the doctor-patient partnership', 'Feminism and family medicine', 'Positive family medicine', 'Mindful practice', 'The new, old ethics of family medicine', 'Public health, prevention and populations', 'Information mastery in family medicine' and 'Clinical courage.' May readers nurture their curiosity through these essays.


Assuntos
Coragem , Fabaceae , Cristalino , Lentes , Unionidae , Humanos , Animais , Medicina de Família e Comunidade , Médicos de Família
2.
Sensors (Basel) ; 24(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610278

RESUMO

Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-µm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20-80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.


Assuntos
Lentes , Imagem Terahertz , Animais , Camundongos , Polietileno , Politetrafluoretileno , Temperatura Baixa
3.
Prog Brain Res ; 284: 111-154, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38609291

RESUMO

At the end of the late Middle Ages, there had been changes in indications for surgery, with prophylactic trepanation falling out of favor. The management of wounds and the methods for opening the cranium had become fairly standardized. Narrow non-plunging trepans were the preferred drills, and cranial openings were widened by the use of multiple drill holes connected with chisels of which the lenticular was preferred. Concerns about damaging the dura led Theodoric to delay trepanation until the clinical changes reflected separation of the dura from the cranium, at least in his view. Draining pus remained the main indication for trepanation. In no case was the level of consciousness considered in determining the need to open the cranium.


Assuntos
Estado de Consciência , Lentes , Pessoa de Meia-Idade , Humanos , Europa (Continente) , Crânio
4.
J Biomed Opt ; 29(3): 036502, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38515831

RESUMO

Significance: The reprojection setup typical of oblique plane microscopy (OPM) limits the effective aperture of the imaging system, and therefore its efficiency and resolution. Large aperture system is only possible through the use of custom specialized optics. A full-aperture OPM made with off the shelf components would both improve the performance of the method and encourage its widespread adoption. Aim: To prove the feasibility of an OPM without a conventional reprojection setup, retaining the full aperture of the primary objective employed. Approach: A deformable lens based remote focusing setup synchronized with the rolling shutter of a complementary metal-oxide semiconductor detector is used instead of a traditional reprojection system. Results: The system was tested on microbeads, prepared slides, and zebrafish embryos. Resolution and pixel throughput were superior to conventional OPM with cropped apertures, and comparable with OPM implementations with custom made optical components. Conclusions: An easily reproducible approach to OPM imaging is presented, eliminating the conventional reprojection setup and exploiting the full aperture of the employed objective.


Assuntos
Lentes , Dispositivos Ópticos , Animais , Microscopia/métodos , Peixe-Zebra , Óptica e Fotônica , Óxidos
5.
Sci Rep ; 14(1): 5292, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438495

RESUMO

To evaluate the visual performance of a diffractive bifocal intraocular lens (IOL) with + 4.0 D near addition (ZMB00) and a diffractive trifocal IOL with + 2.17 D and + 3.25 D near addition (AcrySof IQ PanOptix TFNT00), we investigated the 10-week postoperative parameters after cataract surgery in which ZMB00 or TFNT00 lenses were implanted bilaterally from 2011 to 2020 (with a 3-month interval between implantation of the right and left lenses). The study included 1448 eyes of 724 patients. The diffractive bifocal group comprised 1326 eyes of 663 patients (aged 67.0 ± 7.8 years; females/males, 518/145), and the diffractive trifocal group comprised 122 eyes of 61 patients (aged 66.6 ± 7.3 years; females/males, 35/26). A linear mixed-effects model using data for both eyes, with strict adjustments for sex, age, subjective refraction spherical equivalent, subjective refraction cylinder, corneal astigmatism, axial length, corneal higher-order aberrations, and pupil diameter, ensured statistical validity. Uncorrected near visual acuity and higher-order aberrations (ocular/internal, scaled to a pupil size of 4 mm) (Wavefront_4mm_postoperative_Ocular/Internal_Spherical) were significantly better in the bifocal group (p < 0.00068, Wald test). Uncorrected intermediate visual acuity, contrast sensitivity (6.3/4.0/2.5/1.6/1.0/0.7 degrees), and contrast sensitivity with glare (4.0/1.6/1.0/0.7 degrees) were significantly better in the trifocal group (p < 0.00068, Wald test).


Assuntos
Cristalino , Lentes Intraoculares , Lentes , Feminino , Masculino , Humanos , Olho Artificial , Córnea
6.
Vestn Oftalmol ; 140(1): 11-18, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450461

RESUMO

Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM). PURPOSE: This study assesses the state of the anatomical complex of the lens in MS using UBM. MATERIAL AND METHODS: The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. RESULTS: There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. CONCLUSION: UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal¼ values of UBM indicators of the anatomical complex of the lens.


Assuntos
Ectopia do Cristalino , Cristalino , Lentes , Síndrome de Marfan , Humanos , Ectopia do Cristalino/diagnóstico , Ectopia do Cristalino/etiologia , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Cristalino/diagnóstico por imagem , Iris
7.
Nat Comput Sci ; 4(2): 94-95, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38365998

Assuntos
Cristalino , Lentes , Microscopia , DNA
8.
Cell Rep ; 43(2): 113785, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38363673

RESUMO

Synapses preferentially respond to particular temporal patterns of activity with a large degree of heterogeneity that is informally or tacitly separated into classes. Yet, the precise number and properties of such classes are unclear. Do they exist on a continuum and, if so, when is it appropriate to divide that continuum into functional regions? In a large dataset of glutamatergic cortical connections, we perform model-based characterization to infer the number and characteristics of functionally distinct subtypes of synaptic dynamics. In rodent data, we find five clusters that partially converge with transgenic-associated subtypes. Strikingly, the application of the same clustering method in human data infers a highly similar number of clusters, supportive of stable clustering. This nuanced dictionary of functional subtypes shapes the heterogeneity of cortical synaptic dynamics and provides a lens into the basic motifs of information transmission in the brain.


Assuntos
Cristalino , Lentes , Animais , Humanos , Camundongos , Animais Geneticamente Modificados , Encéfalo , Análise por Conglomerados
9.
Optom Vis Sci ; 101(2): 109-116, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38408308

RESUMO

SIGNIFICANCE: This study provides a faster method for objectively measuring accommodative amplitude with an open-field autorefractor in a research setting. PURPOSE: Objective measures of accommodative amplitude with an autorefractor take time because of the numerous stimulus demands tested. This study compares protocols using different amounts and types of demands to shorten the process. METHODS: One hundred participants were recruited for four age bins (5 to 9, 10 to 14, 15 to 19, and 20 to 24 years) and monocular amplitude measured with an autorefractor using three protocols: proximal, proximal-lens (letter), and proximal-lens (picture). For proximal, measurements were taken as participants viewed a 0.9 mm "E" placed at 13 demands (40 to 3.3 cm = 2.5 to 30 D). The other protocols used a target (either the "E" or a detailed picture) placed at 33 and 12.5 cm followed by 12.5 cm with a series of lenses (-2, -4, and -5.5 D). Adjustments were made for lens effectivity for the three lens conditions, which were thus 9.6, 11.1, and 12.0 D for individuals without additional spectacle lenses. Accommodative amplitude was defined as the greatest response measured with each technique. One-way analysis of variance was used to compare group mean amplitudes across protocols and differences between letter protocols by age bin. RESULTS: Amplitudes were significantly different between protocols (p < 0.001), with proximal having higher amplitudes (mean ± standard deviation, 8.04 ± 1.70 D) compared with both proximal-lens protocols (letter, 7.48 ± 1.42 D; picture, 7.43 ± 1.42 D) by post hoc Tukey analysis. Differences in amplitude between the proximal and proximal-lens (letter) protocol were different by age group (p = 0 .003), with the youngest group having larger differences (1.14 ± 1.58 D) than the oldest groups (0.17 ± 0.58 and 0.29 ± 0.48 D, respectively) by post hoc Tukey analysis. CONCLUSIONS: The proximal-lens protocols took less time and identified the maximum accommodative amplitude in participants aged 15 to 24 years; however, they may underestimate true amplitude in younger children.


Assuntos
Acomodação Ocular , Lentes , Criança , Humanos
10.
Ophthalmic Physiol Opt ; 44(2): 334-346, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38299736

RESUMO

The intracapsular accommodation mechanism (IAM) may be understood as an increase in the lens equivalent refractive index as the eye accommodates. Our goal was to evaluate the existence of an IAM by analysing observed changes in the inner curvature gradient of the lens. To this end, we fitted a gradient index and curvature lens model to published experimental data on external and nucleus geometry changes during accommodation. For each case analysed, we computed the refractive power and equivalent index for each accommodative state using a ray transfer matrix. All data sets showed an increase in the effective refractive index, indicating a positive IAM, which was stronger for older lenses. These results suggest a strong dependence of the lens equivalent refractive index on the inner curvature gradient.


Assuntos
Cristalino , Lentes , Humanos , Refração Ocular , Acomodação Ocular , Refratometria/métodos
11.
Nat Commun ; 15(1): 1031, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310087

RESUMO

The advance of genetic function indicators has enabled the observation of neuronal activities at single-cell resolutions. A major challenge for the applications on mammalian brains is the limited optical access depth. Currently, the method of choice to access deep brain structures is to insert miniature optical components. Among these validated miniature optics, the gradient-index (GRIN) lens has been widely employed for its compactness and simplicity. However, due to strong fourth-order astigmatism, GRIN lenses suffer from a small imaging field of view, which severely limits the measurement throughput and success rate. To overcome these challenges, we developed geometric transformation adaptive optics (GTAO), which enables adaptable achromatic large-volume correction through GRIN lenses. We demonstrate its major advances through in vivo structural and functional imaging of mouse brains. The results suggest that GTAO can serve as a versatile solution to enable large-volume recording of deep brain structures and activities through GRIN lenses.


Assuntos
Cristalino , Lentes , Camundongos , Animais , Óptica e Fotônica , Encéfalo/diagnóstico por imagem , Neuroimagem , Mamíferos
12.
J Dent Educ ; 88(4): 461-467, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38229449

RESUMO

OBJECTIVE: This study aimed to evaluate the visual acuity and working distance of dental students using Galilean loupes at different magnification levels. METHODS: The participants included 50 undergraduate dentistry students selected from each class in the second to fifth years (N = 200) of São Paulo State University, School of Dentistry, Araraquara. The response variables were (i) the working distance between the operator's eyes and the mouth of the dental phantom head, and (ii) visual acuity. The independent variables were the five levels of the Galilean magnification system (naked eye, Galilean loupe simulator without magnification, and Galilean loupes with 2.5×, 3.0×, or 3.5× magnification) and academic year. Visual acuity was measured using a miniature Snellen eye chart inserted into the Class I cavities of the maxillary molars. After verifying the assumptions of normality and sphericity, a mixed repeated measures analysis was performed (α = 0.05). RESULTS: Statistical significance was found between the "magnification system" and "academic year" for visual acuity (p < 0.001). For the second-, fourth-, and fifth-year participants, there were no significant differences in visual acuity between the naked eye and different magnifications of the Galilean loupes, which were superior to and significantly different from that of the loupe simulator. For the working distance, statistical significance was observed in the interaction between "magnification system" and "academic year" (p = 0.008). For the third-, fourth-, and fifth-year participants, there was no significant difference in the working distance between the naked eye and different magnifications of the Galilean loupes, which were superior to and significantly different from that of the simulator. CONCLUSION: It was concluded that the different magnification levels of the Galilean loupes did not influence the visual acuity or distance between the eyes of the operator and the mouth of the dental phantom head in the evaluated students.


Assuntos
Lentes , Estudantes de Odontologia , Humanos , Microscopia , Brasil , Acuidade Visual
13.
Appl Opt ; 63(1): 193-203, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38175021

RESUMO

Bio-inspired optical systems have recently been developed using polarizers and liquid or rigid lenses. In this work, we propose a bio-inspired opto-mechatronic system that imitates the accommodation and regulation of light intensity as the human eye does. The system uses a polymeric lens as a cornea, an adjustable diaphragm as an iris, a tunable solid elastic lens as a crystalline lens, and a commercial sensor as a retina. We also present the development of the electronic control system to accommodate and regulate the amount of light that enters the system, for which two stepper motors, an Arduino control system, and light and movement sensors are used. The characterization of the system is presented together with the results obtained, where it can be seen that the system works in an acceptable range as the human eye does.


Assuntos
Cristalino , Lentes , Dispositivos Ópticos , Humanos , Iluminação , Córnea
14.
PLoS One ; 19(1): e0295513, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38198470

RESUMO

Partisan animosity has been on the rise in America. Partisan animosity involves blame, wherein political partisans blame outparty members for their beliefs and actions. Here, we examine whether a historicist thinking intervention-drawn from research on blame mitigation-can reduce partisan animosity. The intervention consisted of three components: (1) a narrative about the idiosyncratic development of one political opponent paired with (2) a message about how unique life experiences shape everyone's political beliefs and (3) a suggestion that outparty members can be changed by future formative experiences. Experiments 1 and 2 showed that the intervention reduced cold feelings-measured via Feeling Thermometer-towards the outparty for both Democrats and Republicans. Experiments 3 and 4 focused on more specific emotional changes. Experiment 3 showed that, for Democrats, the intervention increased compassion. Experiment 4 showed that, for Republicans, the intervention reduced disgust, disapproval, anger, and contempt, but had no impact on compassion. For Democrats, but not for Republicans, reductions in animosity were mediated by reduced perceptions of control of self-formation, the mediator identified in prior work on historicist thinking and blame mitigation.


Assuntos
Cristalino , Lentes , Unionidae , Animais , Emoções , Ira
15.
Stud Health Technol Inform ; 310: 976-980, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38269954

RESUMO

We describe the development and usability evaluation of a novel patient engagement tool (OPY) in its early stage from perspectives of both experts and end-users. The tool is aimed at engaging patients in positive behaviors surrounding the use, weaning, and disposal of opioid medications in the post-surgical setting. The messaging and design of the application were created through a behavioral economics lens. Expert-based heuristic analysis and user testing were conducted and demonstrated that while patients found the tool to be easy to use and subjectively somewhat useful, additional work to enhance the user interface and features is needed in close partnership with developers and stakeholders.


Assuntos
Lentes , Aplicativos Móveis , Humanos , Analgésicos Opioides/uso terapêutico , Economia Comportamental , Heurística
16.
Nurs Open ; 11(1): e2073, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38268253

RESUMO

AIM: This study aimed to illuminate meanings of person-centredness as narrated by nursing home managers in nursing homes rated as highly person-centred. DESIGN: A phenomenological hermeneutical approach was used. METHODS: Twelve nursing home managers in 11 highly person-centred nursing homes in 7 municipalities in Sweden were included in this interview study. The findings were interpreted, reflected and discussed through the lens of Ricoeur. RESULTS: Meanings of person-centredness could be understand as moving between doing and being through knowing, sensing, sharing and giving for person-centredness. These aspects contributed via knowledge, understanding, interaction and action that involved doing for and being with older persons through these caring dimensions. By moving between doing for, being with and being part of the overall nursing home narrative, knowing, sensing, sharing and giving could support the persons' identity in different ways. This may also contribute to sense-making, preserving dignity and promoting self-esteem when aiming to provide a good life for older persons in nursing homes, within an ever-present ethical frame. NO PATIENT OR PUBLIC CONTRIBUTION: This study illuminated meanings of person-centredness as narrated by nursing home managers. No patient of public contribution was investigated.


Assuntos
Cristalino , Lentes , Humanos , Idoso , Idoso de 80 Anos ou mais , Casas de Saúde , Instituições de Cuidados Especializados de Enfermagem , Conhecimento
18.
Eval Rev ; 48(1): 90-118, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37092672

RESUMO

The global economies and international organizations are inclined towards sustainable growth, technological advancements and product innovations. China is the leading economy in information and communication technologies and among the major industrially expanded economies covering a substantial share of the global market in exports. The prime objective of this study is to explore the role of digitalization and Information and communication technologies (ICT) for product innovation (PIN). In doing so, the study also attempts to draw some novel implications regarding business, entrepreneurship, and product innovation in the lens of sustainability. This current study use the annual data of China from 1990-2020. The empirical analysis was conducted using the stationarity testing and the Johansen cointegration test. In addition, due to the data's asymmetrical distribution, the non-parametric "quantile regression" is used. For robustness, this study employs the Fully Modified Ordinary Least Square, Canonical Cointegration, and Dynamic Ordinary Least Square methods. The empirical results reveal that economic progress and financial development are substantial factors of product innovation. The robust analysis reveals that medium and high-tech industries and information and communication technology adversely affect product innovation. Further, the presence of financial development transforms the negative influence of information and communication technology into a positive. The current study concludes more investments in the technological industry are required to encourage product innovation in China. The study discusses some policy-related implications in the context of business sustainability and product innovation.


Assuntos
Cristalino , Lentes , Unionidae , Animais , Tecnologia da Informação , Comunicação , China
19.
Artigo em Inglês | MEDLINE | ID: mdl-38059130

RESUMO

During minimal invasive surgery (MIS), the laparoscope only provides a single viewpoint to the surgeon, leaving a lack of 3D perception. Many works have been proposed to obtain depth and 3D reconstruction by designing a new optical structure or by depending on the camera pose and image sequences. Most of these works modify the structure of the conventional laparoscopes and cannot provide 3D reconstruction of different magnification views. In this study, we propose a laparoscopic system based on double liquid lenses, which provide doctors with variable magnification rates, near observation, and real-time monocular 3D reconstruction. Our system composes of an optical structure that can obtain auto magnification change and autofocus without any physically moving element, and a deep learning network based on the Depth from Defocus (DFD) method, trained to suit inconsistent camera intrinsic situations and estimate depth from images of different focal lengths. The optical structure is portable and can be mounted on conventional laparoscopes. The depth estimation network estimates depth in real-time from monocular images of different focal lengths and magnification rates. Experiments show that our system provides a 0.68-1.44x zoom rate and can estimate depth from different magnification rates at 6fps. Monocular 3D reconstruction reaches at least 6mm accuracy. The system also provides a clear view even under 1mm close working distance. Ex-vivo experiments and implementation on clinical images prove that our system provides doctors with a magnified clear view of the lesion, as well as quick monocular depth perception during laparoscopy, which help surgeons get better detection and size diagnosis of the abdomen during laparoscope surgeries.


Assuntos
Laparoscopia , Cristalino , Lentes , Laparoscópios , Laparoscopia/métodos , Abdome
20.
Nat Commun ; 14(1): 8103, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081825

RESUMO

Autonomous migration is essential for the function of immune cells such as neutrophils and plays an important role in numerous diseases. The ability to routinely measure or target it would offer a wealth of clinical applications. Video microscopy of live cells is ideal for migration analysis, but cannot be performed at sufficiently high-throughput (HT). Here we introduce ComplexEye, an array microscope with 16 independent aberration-corrected glass lenses spaced at the pitch of a 96-well plate to produce high-resolution movies of migrating cells. With the system, we enable HT migration analysis of immune cells in 96- and 384-well plates with very energy-efficient performance. We demonstrate that the system can measure multiple clinical samples simultaneously. Furthermore, we screen 1000 compounds and identify 17 modifiers of migration in human neutrophils in just 4 days, a task that requires 60-times longer with a conventional video microscope. ComplexEye thus opens the field of phenotypic HT migration screens and enables routine migration analysis for the clinical setting.


Assuntos
Cristalino , Lentes , Humanos , Microscopia , Microscopia de Vídeo , Movimento Celular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...